CSMIP: Oakland, CA
18-story City Hall
Agency Number:
58675
Structure:
18-story bldg
Site Geology:
Deep alluvium
Owner:
California Strong Motion Instrumentation Program
(external link)
Owner's Station Page
References
Add all data on this page to the download bin
View Map
Lafayette, California 2007-03-02 04:40:00 UTC
Hypocentral dist:
24.9 km
Summary page for this earthquake
Plot Acceleration
Basement (below isolators): W
Add this instrument's data to the download bin
Component:
Up
PGA (cm/s/s):
6.64
PGV (cm/s):
-0.23
Add this to bin
Basement (below isolators): E
Add this instrument's data to the download bin
Component:
Up
PGA (cm/s/s):
6.49
PGV (cm/s):
-0.18
Add this to bin
Basement (below isolators): N
Add this instrument's data to the download bin
Component:
90
PGA (cm/s/s):
12.85
PGV (cm/s):
-0.59
Add this to bin
Basement (below isolators): S
Add this instrument's data to the download bin
Component:
90
PGA (cm/s/s):
12.58
PGV (cm/s):
-0.54
Add this to bin
Basement (below isolators): Ctr
Add this instrument's data to the download bin
Component:
360
PGA (cm/s/s):
-12.44
PGV (cm/s):
-0.42
Add this to bin
1st Floor (above isolators): W
Add this instrument's data to the download bin
Component:
Up
PGA (cm/s/s):
7.98
PGV (cm/s):
-0.17
Add this to bin
1st Floor (above isolators): E
Add this instrument's data to the download bin
Component:
Up
PGA (cm/s/s):
9.41
PGV (cm/s):
-0.21
Add this to bin
1st Floor (above isolators): N
Add this instrument's data to the download bin
Component:
90
PGA (cm/s/s):
10.37
PGV (cm/s):
-0.57
Add this to bin
1st Floor (above isolators): S
Add this instrument's data to the download bin
Component:
90
PGA (cm/s/s):
9.24
PGV (cm/s):
-0.50
Add this to bin
1st Floor (above isolators): Ctr
Add this instrument's data to the download bin
Component:
360
PGA (cm/s/s):
-9.85
PGV (cm/s):
-0.50
Add this to bin
7th Floor: Near N Wall
Add this instrument's data to the download bin
Component:
90
PGA (cm/s/s):
15.98
PGV (cm/s):
-0.81
Add this to bin
Component:
360
PGA (cm/s/s):
-18.00
PGV (cm/s):
-1.05
Add this to bin
7th Floor: Near S Wall
Add this instrument's data to the download bin
Component:
90
PGA (cm/s/s):
15.97
PGV (cm/s):
0.88
Add this to bin
14th Floor: N Wall
Add this instrument's data to the download bin
Component:
90
PGA (cm/s/s):
-14.94
PGV (cm/s):
-1.22
Add this to bin
14th Floor: S Wall
Add this instrument's data to the download bin
Component:
90
PGA (cm/s/s):
-17.31
PGV (cm/s):
-1.42
Add this to bin
14th Floor: near Ctr
Add this instrument's data to the download bin
Component:
360
PGA (cm/s/s):
-14.92
PGV (cm/s):
-0.81
Add this to bin
18th Floor: near Ctr
Add this instrument's data to the download bin
Component:
90
PGA (cm/s/s):
-38.09
PGV (cm/s):
3.67
Add this to bin
Component:
360
PGA (cm/s/s):
26.76
PGV (cm/s):
-2.26
Add this to bin
Main Roof: N Wall
Add this instrument's data to the download bin
Component:
90
PGA (cm/s/s):
10.82
PGV (cm/s):
-0.71
Add this to bin
Component:
360
PGA (cm/s/s):
-14.59
PGV (cm/s):
-0.85
Add this to bin
Main Roof: S Wall
Add this instrument's data to the download bin
Component:
90
PGA (cm/s/s):
-12.12
PGV (cm/s):
0.85
Add this to bin
Return to top
Home
+
Login
+
Download
+
About Us
+
Contact
Earthquakes
+
stations
+
Search
+
Map
+
Advanced Search